1.877.817.6028
www.DiodeLED.com
INSTALLATION GUIDE
[email protected] www.DiodeLED.com
2 OF 2
DMX 8-WAY SPLITTER
®
Visit the on-line product page at www.DiodeLED.com for addional product specicaons & warranty informaon.
DMX 8-WAY SPLITTER Specicaon Sheet
For full specicaons.
Voltage Drop Charts
Use to specify appropriate wire gauge for installaon. Available at the ‘Tools & Resources’ page at www.DiodeLED.com.
Additional Resources
QUESTIONS?
Visit www.DiodeLED.com or contact Customer Support at inf[email protected]
or 1.877.817.6028 Monday through Friday, 7:00am - 5:00pm PST.
Wiring Connections
1 2
3
12
3
+
-
Input From
12-24V Driver
DMX-512 Output
(8x Female XLR-3 Connections)
DMX-512 Input
(Male XLR-3 Connection)
(Requires Male DC Plug, 5.5 x 2.1mm)
Pin 1: Ground
Pin 2: Data -
Pin 3: Data +
DO NOT connect directly to 120VAC. Install in accordance with the NEC, and local regulaons.
IG061714-1.1
Troubleshooting
LED xture responding incorrectly
Ensure all wiring connecons are correct. Reversing the Data + and Data - will cause lights to icker
and not respond to controller:
Check power connecons of all components (drivers, DMX decoders/xtures, DMX controller).
Ensure a compable constant voltage driver is installed.
Ensure the driver and DMX xture have the same voltage specicaons (12V & 12V, or 24V & 24V).
Fixture is ashing or ickering
Verify a compable constant voltage driver is installed.
Ensure all connecons are properly secured.
Prior to troubleshoong, ensure a compable system is installed. Verify compable xtures, drivers, controls and addional components were specied correctly.